Altronix MAXIMAL3V 12VDC/24VDC 6A, 16 Fused, 220V Power Supply for Security Systems
MAXIMAL3V|AX-MAXIAL3V
Altronix MAXIMAL3V 12VDC/24VDC 6A, 16 Fused, 220V Power Supply for Security Systems
MAXIMAL3V|AX-MAXIAL3V

Altronix
Altronix MAXIMAL3V 12VDC/24VDC 6A, 16 Fused, 220V Power Supply for Security Systems
MAXIMAL3V | AX-MAXIAL3V
Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.
Aperçu
Spécifications
Documents
Aperçu
Introducing the Altronix MAXIMAL3V, a powerful solution for your access control needs. This unit efficiently converts 220V AC into sixteen independently controlled 12V DC or 24V DC outputs, each protected by fuses. Designed for versatility, it supports various access control devices such as mag locks and electric strikes, operating in both fail-safe and fail-secure modes. The FACP interface allows for emergency egress and alarm monitoring, ensuring safety and reliability. With its robust features, the MAXIMAL3V is perfect for enhancing your security systems. Don't miss out on this essential addition to your setup – order yours today!
Principales caractéristiques
Renseignements généraux
Name: Altronix MAXIMAL3V 12VDC/24VDC 6A, 16 Fused, 220V Power Supply for Security Systems
Category:
UPC Code:
Country of Origin: . Country of origin is subject to change.
Spécifications
ADI Numéro du produit AX-MAXIAL3V Code fabricant MAXIMAL3V Fabricant Altronix Corporation Gamme Maximal R Genre du connecteur Access Control Marque Altronix Modèle de produit MAXIMAL3V Nom de produit Access Power Controller With Power Supply/Charger, 16 Fused Relay Outputs, 12/24VDC at 6A, 220VAC, BC800 Enclosure Type de produit Access Power Controller
Nombre de porte(s) 16 Tension de sortie 12V DC, 24V DC
NDAA Compliant Yes
Température de fonctionnement 32-120°F Temperature de stockage (T-T) -4-158°F
Hauteur 26" Largeur 19" Poids 42.3lb Profondeur 6.25"
Tension d'entrée 220V AC
Garantie Limitée Lifetime
Caractéristiques AC fail supervision (form "C" contacts), Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC), Capacity 12AH/12VDC (4 within enclosure); 40AH/65AH (requires separate enclosure), Failover: Upon AC loss, instantaneous., Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs, Low battery and battery presence supervision (form "C" contact), Normally open (NO) or normally closed (NC) dry contact input, Notification trigger is selectable for 30 seconds (factory set) or 6 hours, Polarity reversal input from FACP signaling circuit, Type Sealed lead acid or gel type Certification environnementale RoHS