Image of AX-MAXIMA5FV

Altronix MAXIMAL55FV Access Power Controller with Power Supply / Chargers, 16 Fused Relay Outputs, Dual 12VDC P/S at 9.5A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

MAXIMAL55FV|AX-MAXIMA5FV

Altronix MAXIMAL55FV Access Power Controller with Power Supply / Chargers, 16 Fused Relay Outputs, Dual 12VDC P/S at 9.5A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

MAXIMAL55FV|AX-MAXIMA5FV

Se connecter prix revendeur

Devenir client ADI
Image of AX-MAXIMA5FV
Altronix

Altronix MAXIMAL55FV Access Power Controller with Power Supply / Chargers, 16 Fused Relay Outputs, Dual 12VDC P/S at 9.5A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

MAXIMAL55FV | AX-MAXIMA5FV

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

Introducing the Altronix MAXIMAL55FV, a powerful access power controller designed to efficiently distribute and manage power for your access control systems and accessories. This unit transforms a 220V AC input into sixteen independently controlled 12V DC outputs, each protected by fuses. With versatile Fail-Safe/Fail-Secure outputs, you can easily connect to various access control devices such as mag locks and electric strikes. The FACP interface supports emergency egress and alarm monitoring, ensuring safety and reliability. Upgrade your security system with the Altronix MAXIMAL55FV and experience seamless power management. Don't miss out—order yours today!

Principales caractéristiques

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
  • Normally open (NO) or normally closed (NC) dry contact input
  • Polarity reversal input from FACP signaling circuit
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated at 1A 28V DC)
  • AC fail supervision (form "C" contacts)
  • Notification trigger is selectable for 30 seconds (factory set) or 2 hours
  • Low battery and battery presence supervision (form "C" contact)
  • Capacity: 12AH/12V DC (4 within enclosure); 40AH/65AH (requires separate enclosure)
  • Type Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous