adi-insite-ca
ADI US App
ADI Global Distribution
ADI a Resideo company
menu
Image of AX-MAXIMAL5V

Altronix MAXIMAL5V Access Power Controller with Power Supply / Charger, 16-Fused Relay Relay Outputs, 12VDC 9A, 220VAC, BC800 Enclosure

MAXIMAL5V|AX-MAXIMAL5V

Altronix MAXIMAL5V Access Power Controller with Power Supply / Charger, 16-Fused Relay Relay Outputs, 12VDC 9A, 220VAC, BC800 Enclosure

MAXIMAL5V|AX-MAXIMAL5V

Se connecter prix revendeur

Devenir client ADI
Image of AX-MAXIMAL5V
Altronix

Altronix MAXIMAL5V Access Power Controller with Power Supply / Charger, 16-Fused Relay Relay Outputs, 12VDC 9A, 220VAC, BC800 Enclosure

MAXIMAL5V | AX-MAXIMAL5V

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

Introducing the Altronix MAXIMAL5V Access Power Controller, a reliable solution for managing power to your access control systems and accessories. This innovative device transforms a 220V AC input into sixteen independently controlled 12V DC outputs, each protected by fuses. Designed for versatility, it supports various access control hardware, including mag locks and electric strikes. The FACP Interface allows for emergency egress and alarm monitoring, ensuring safety and efficiency. With its selectable fire alarm disconnect feature, you can customize the outputs to meet your needs. Enhance your security setup today with the Altronix MAXIMAL5V!

Principales caractéristiques

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
  • Normally open (NO) or normally closed (NC) dry contact input
  • Polarity reversal input from FACP signaling circuit
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated at 1A 28V DC)
  • AC fail supervision (form "C" contacts)
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours
  • Low battery and battery presence supervision (form "C" contact)
  • Capacity: 12AH/12V DC (4 within enclosure); 40AH/65AH (requires separate enclosure)
  • Type Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous
  • Renseignements généraux

    Name: Altronix MAXIMAL5V Access Power Controller with Power Supply / Charger, 16-Fused Relay Relay Outputs, 12VDC 9A, 220VAC, BC800 Enclosure
    Category:
    UPC Code:
    Country of Origin: . Country of origin is subject to change.

    Spécifications