adi-insite-ca
ADI US App
ADI Global Distribution
ADI a Resideo company
menu
System Sensor D4120A 4-Wire Duct Detector, 24VDC/120VAC
System Sensor

System Sensor D4120A 4-Wire Photoelectric Low-Flow Duct Smoke Detector, 24VDC/120VAC

D4120A|BK-D4120A
System Sensor

System Sensor D4120A 4-Wire Photoelectric Low-Flow Duct Smoke Detector, 24VDC/120VAC

D4120A|BK-D4120A

Se connecter prix revendeur

Devenir client ADI
System Sensor D4120A 4-Wire Duct Detector, 24VDC/120VAC
System Sensor

System Sensor D4120A 4-Wire Photoelectric Low-Flow Duct Smoke Detector, 24VDC/120VAC

D4120A | BK-D4120A

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

The air duct smoke detector shall be a System Sensor InnovairFlex D4120A Photoelectric Duct Smoke Detector. The detector housing shall be ULC listed specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the RTS151KEYA Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring..

Principales caractéristiques

  • Patented sAling tube installs from front or back of the detector with no tools required
  • IncreasedWiring space with a newly added 3/4 inch conduit knockout
  • One easy-access Test/Reset button and improved LED status
  • Patented interconnect feature for multi-fan shutdown
  • New high contrast terminal designations
  • Built-in short circuit protection from operator wiring errors
  • Field selectable settings for configuring the detector
  • Two DPDT Form C relay contacts
  • 24V AC/DC or 120V AC
  • Backward compatibility with existing Innovair products, including remote accessories
  • Renseignements généraux

    Name: System Sensor D4120A 4-Wire Photoelectric Low-Flow Duct Smoke Detector, 24VDC/120VAC
    Category:
    UPC Code:
    Country of Origin: MX. Country of origin is subject to change.

    Spécifications