adi-insite-ca
ADI US App
ADI Global Distribution
ADI a Resideo company
menu
Image of FL-MRP2001C

Fire-Lite MRP-2001C Fire Alarm Control Panel

MRP-2001C|FL-MRP2001C

Fire-Lite MRP-2001C Fire Alarm Control Panel

MRP-2001C|FL-MRP2001C

Se connecter prix revendeur

Devenir client ADI
Image of FL-MRP2001C

Fire-Lite MRP-2001C Fire Alarm Control Panel

MRP-2001C | FL-MRP2001C

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

The MRP-2001C is a six-zone FACP for single and dual hazard deluge and preaction applications. The MRP-2001C provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing. The MRP-2001C is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 7.22°C. In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normallyopen contact devices. Refer to the Fire Lite Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2001C supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel’s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.

Principales caractéristiques

  • Designed for sprinkler standards NFPA 13, 15, and 16
  • Dual hazard operation
  • Adjustable waterflow discharge timer and two soak timers
  • Cross-zone (double-interlock) capability
  • Six programmable Style B (Class B) IDCs (Initiating Device Circuit)
  • System Sensor i3 series detectors compatible
  • 3-Programmable Form-C relays
  • 7.0 amps Total 24 VDC output current
  • Resettable and non-resettable output power
  • Built-in Programmer
  • Renseignements généraux

    Name: Fire-Lite MRP-2001C Fire Alarm Control Panel
    Category:
    UPC Code: 783008110512
    Country of Origin: . Country of origin is subject to change.

    Spécifications