adi-insite-ca
ADI US App
ADI Global Distribution
ADI a Resideo company
menu
Image of FL-MRP2002C

Fire-Lite MRP-2002C Agent Release Control Panel, 6-Zone, 24V

MRP-2002C|FL-MRP2002C

Fire-Lite MRP-2002C Agent Release Control Panel, 6-Zone, 24V

MRP-2002C|FL-MRP2002C

Se connecter prix revendeur

Devenir client ADI
Image of FL-MRP2002C

Fire-Lite MRP-2002C Agent Release Control Panel, 6-Zone, 24V

MRP-2002C | FL-MRP2002C

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

The MRP-2002C is a six-zone FACP for single and dual hazard agent releasing applications. The MRP-2002C provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The MRP-2002C is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 7.22°C. In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2002C supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normally open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel’s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.

Principales caractéristiques

  • Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001
  • Meets International Building Code (IBC) seismic requirements
  • Disable/Enable control per input zone and output zone
  • Extensive transient protection
  • Dual hazard operation
  • Adjustable pre-discharge, discharge and waterflow delay timers
  • Cross-zone (double-interlock) capability
  • System Sensor i3 series detector compatible
  • Three programmable Form-C relays
  • Resettable and non-resettable output power
  • Renseignements généraux

    Name: Fire-Lite MRP-2002C Agent Release Control Panel, 6-Zone, 24V
    Category:
    UPC Code: 783008110529
    Country of Origin: . Country of origin is subject to change.

    Spécifications