The MS-5UD-7C is a five-zone FACP (Fire Alarm Control Panel) and the MS-10UD-7C is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor’s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory “freeze” signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-7C and MS10UD-7C are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function.

Principales caractéristiques

  • Built-in DACT (Digital Alarm Communicator/Transmitter)
  • Optional CAC-5X Style Z (Class A) Converter Module for NACs and IDCs (2 required for MS-10UD-7C)
  • 7.0 A total system current for MS-10UD-7C
  • Optional Trim Ring for semi-flush mounting
  • Low AC voltage sense
  • Alarm Verification
  • Automatic battery trickle charger
  • Optional 4XTMF module (conventional reverse polarity/city box transmitter)
  • Renseignements généraux

    Name: Fire-Lite MS-10UD-7C-FR 10-Zone Fire Alarm Control Panel, 24V
    Category:
    UPC Code: 783008111717
    Country of Origin: United States. Country of origin is subject to change.