Image of L1-SCR15GFPM

Lutron SCR-15-GFST-PM Receptacle Self-Testing GFCI, 15A, Satin Pumice

SCR-15-GFST-PM|L1-SCR15GFPM

Lutron SCR-15-GFST-PM Receptacle Self-Testing GFCI, 15A, Satin Pumice

SCR-15-GFST-PM|L1-SCR15GFPM

Se connecter prix revendeur

Devenir client ADI
Image of L1-SCR15GFPM
Lutron Electronics

Lutron SCR-15-GFST-PM Receptacle Self-Testing GFCI, 15A, Satin Pumice

SCR-15-GFST-PM | L1-SCR15GFPM

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

The Lutron SCR-15-GFST-PM is a self-testing GFCI receptacle designed for optimal safety and reliability. It features continuous self-testing that disconnects power if protection is compromised, starting within 2.5 seconds and cycling every 30 seconds to ensure nonstop monitoring. The manual test simulates ground faults to verify full system functionality, while the reverse wire safety prevents power if wired incorrectly. Equipped with a tamper-resistant shutter and easy internal back wiring, it fits NEMA designer wallplates and complies with NEC standards. Enhance your safety with this dependable receptacle today!

Principales caractéristiques

  • Continuous self-test functionality disconnects power to receptacle if critical components are damaged and GFCI protection is lost providing "continuous self-testing" that initiates within 2.5 seconds and is a continuous cycle every 30 seconds or less
  • Manual Test this design incorporates a full system test function the GFCI, when manually tested, induces a simulated ground fault leakage current to the printed circuit board this in turn causes the mechanical system to react based on the action of the solenoid the entire mechanical and electronic GFCI system is reviewed for functionality
  • Reverse wire safety feature if wired incorrectly there will be no power to the face or to downstream receptacles for added safety
  • Permanently installed internal tamper-resistant shutter mechanism capable of resisting insertion of foreign elements into the device
  • Internal back wiring clamp and guide pocket quick and dependable termination
  • Receptacle face compatible with NEMA designer and NovaT designer-opening wallplates
  • Compliant with NEC 406.12 and NEC 517-18
  • Renseignements généraux

    Name: Lutron SCR-15-GFST-PM Receptacle Self-Testing GFCI, 15A, Satin Pumice
    Category:
    UPC Code: 784276809702
    Country of Origin: . Country of origin is subject to change.

    Spécifications