adi-insite-ca
ADI US App
ADI Global Distribution
ADI a Resideo company
menu
Image of TC-PDUMH15AS

Eaton Tripp Lite PDUMH15ATS Single-Phase Local Metered Automatic Transfer Switch PDU, 2 120V 5-15P 15A Inputs, 8 5-15R Outputs, 1U, TAA, 1.4KW

PDUMH15ATS|TC-PDUMH15AS

Eaton Tripp Lite PDUMH15ATS Single-Phase Local Metered Automatic Transfer Switch PDU, 2 120V 5-15P 15A Inputs, 8 5-15R Outputs, 1U, TAA, 1.4KW

PDUMH15ATS|TC-PDUMH15AS

Se connecter prix revendeur

Devenir client ADI
Image of TC-PDUMH15AS
Eaton Tripp Lite

Eaton Tripp Lite PDUMH15ATS Single-Phase Local Metered Automatic Transfer Switch PDU, 2 120V 5-15P 15A Inputs, 8 5-15R Outputs, 1U, TAA, 1.4KW

PDUMH15ATS | TC-PDUMH15AS

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

Single-Phase 15A ATS PDU Distributes and Monitors Network-Grade Power in Real TimeThis local metered rack PDU (rPDU) provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH15ATS features eight NEMA 5-15R 120V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with NEMA 5-15P inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.Switches from Primary to Secondary Power Source in MillisecondsAutomatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.Mounts into 1U of Rack Space or on a WallUse the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.TAA-Compliant for GSA Schedule PurchasesThe PDUMH15ATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Principales caractéristiques

  • 1.44kW 120V Single-Phase ATS PDU
  • 8 NEMA 5-15R Outlets for Equipment
  • Dual 5-15P Inputs with 12' Cords
  • Real-Time Local Metered Reporting
  • Automatic Transfer Switching in 2-7 ms
  • Digital Load Meter Prevents Overloads
  • Mounts in 1U Rack Space or Wall